2688556 Phoenix Contact Programmable Logic Controllers
Part#:2688556
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 12
04/19/2024
About the product: Axioline F, Temperature recording module, Analog inputs: 4 (for resistance temperature detectors), connection method: 2-, 3-, 4-conductor (shielded), transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2688556 Phoenix Contact price in the box on the right side or send a quick quote.
2688556 Product Details
- ECLASS 4.1 27240400
- Width 35 mm
- Conductor cross section solid min. 0.2 mm²
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section AWG max. 16
- Number 2
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Nominal value of the current sources 1 mA (Pt 100, Ni 100, RLin 500 Ω; pulse current, the specification is valid during the sampling phase)
- Data formats IB IL, S7-compatible
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 9.0 27242601
- ETIM 4.0 EC001599
- UNSPSC 11 39121311
- ETIM 6.0 EC001596
- Input name Analog inputs
- Linear resistance measuring range 0 Ω ... 500 Ω
- Type of protection Short-circuit protection, overload protection of the inputs
- Height 126.1 mm
- Test section 5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 10.0.1 27242601
- UNSPSC 18.0 32151602
- UNSPSC 12.01 39121311
- UNSPSC 19.0 32151602
- Designation Supply for analog modules (UA)
- Stripping length 8 mm
- Mounting position any (no temperature derating)
- Power consumption max. 1.1 W (at UBus and UA)
- Conductor cross section AWG min. 24
- Net weight 144 g
- Transmission speed 100 Mbps
- Description of the input Inputs for resistive temperature sensors
- Measured value representation 16 bits (15 bits + sign bit)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 5.1 27242600
- ECLASS 6.0 27242600
- UNSPSC 6.01 43172015
- UNSPSC 21.0 32151602
- Connection method Push-in connection
- Conductor cross section flexible min. 0.2 mm²
- Color traffic grey A RAL 7042
- Current consumption max. 17 mA
- Number of inputs 4 (for resistance temperature detectors)
- Sensor types (RTD) that can be used Pt, Ni, KTY, Cu sensors
- Input filter time 40 ms
- Interference emission Noise emission test according to EN 61000-6-3 Class B
- REACh SVHC Lead 7439-92-1
- ECLASS 4.0 27240400
- UNSPSC 13.2 32151602
- ECLASS 11.0 27242601
- Degree of protection IP20
- Mounting type DIN rail
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Supply voltage 24 V DC
- Protective circuit Surge protection electronic (35 V, 0.5 s)
- Connection technology 2-, 3-, 4-conductor (shielded)
- A/D converter resolution 24 bit
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 5.0 27242200
- UNSPSC 7.0901 43201404
- UNSPSC 20.0 32151602
- Depth 54 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Note on weight specifications with connectors and bus base module
- ETIM 3.0 EC001599
- Caption Dimensional drawing
- Ambient temperature (operation) -25 °C ... 60 °C
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section flexible max. 1.5 mm²
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- ECLASS 7.0 27242601
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Conductor cross section solid max. 1.5 mm²
- ETIM 7.0 EC001596
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
This item can ship within 24h!
1-year warranty
$596.50
2688556
Stock:
12
Select Qty:
$596.50
$596.50 each
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨