2688530 Phoenix Contact Programmable Logic Controllers
Part#:2688530
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
About the product: Axioline F, Bus coupler, PROFIBUS DP, D-SUB-9 female connector, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2688530 Phoenix Contact price in the box on the right side or send a quick quote.
2688530 Product Details
- Width 45 mm
- Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Conductor cross section solid max. 1.5 mm²
- Note on weight specifications with connector and bus base module
- Transmission speed 100 Mbps
- Number of supported devices max. 63 (per station)
- Power consumption max. 13.7 W (2.0 A on UBus, UL = 24 V)
- Height 125.9 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above sea level)
- Connection method Micro USB type B
- Conductor cross section flexible max. 1.5 mm²
- Mounting position any (observe temperature derating)
- Amount of process data max. 488 Byte (per station)
- Current consumption max. 567 mA (with 2 A at UBus for the I/Os and UL = 24 V)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section flexible min. 0.2 mm²
- Net weight 175 g
- Degree of pollution 2 (IEC 60664-1, EN 60664-1)
- Number of local bus devices that can be connected max. 63
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
- China RoHS Environmentally Friendly Use Period = 50 years
- Depth 74 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 24
- Mounting type DIN rail mounting
- Stripping length 8 mm
- Number of configuration data max. 244 Byte
- Supply voltage 5 V DC (via bus base module)
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242608
- ETIM 3.0 EC001604
- Ambient temperature (operation) -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail)
- Designation Axioline F local bus supply (UBus)
- Conductor cross section AWG max. 16
- Color traffic grey A RAL 7042
- Number of interfaces 1
- Number of parameter data max. 244 Byte
- Type of protection Surge protection
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 4.1 27240400
- Power supply unit 2 A
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- ECLASS 9.0 27242608
- UNSPSC 6.01 43172015
- Overvoltage category II (IEC 60664-1, EN 60664-1)
- ECLASS 10.0.1 27242608
- ETIM 6.0 EC001604
- UNSPSC 7.0901 43201404
- UNSPSC 13.2 32151602
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 7.0 27242608
- UNSPSC 11 39121311
- UNSPSC 19.0 32151602
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
- ECLASS 5.0 27242200
- ECLASS 6.0 27242600
- ETIM 4.0 EC001604
- UNSPSC 18.0 32151602
- ETIM 7.0 EC001604
- ECLASS 4.0 27240400
- UNSPSC 21.0 32151602
- UNSPSC 12.01 39121311
- UNSPSC 20.0 32151602
- ECLASS 5.1 27242600
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- Interference emission Noise emission test according to EN 61000-6-3 Class B
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2688530
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨