2688022 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2688022 Axioline F, Digital input module, Digital inputs: 16, 24 V DC, connection method: 4-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Phoenix Contact

Part#:2688022

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Axioline F, Digital input module, Digital inputs: 16, 24 V DC, connection method: 4-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2688022 Phoenix Contact price in the box on the right side or send a quick quote.

2688022 Product Details

  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section AWG max.
    16
  • Color
    traffic grey A RAL 7042
  • Number
    2
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Protection
    max. 8 A (polarity reversal protection up to 5 A)
  • Nominal input voltage UIN
    24 V DC
  • Depth
    54 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Connection method
    Push-in connection
  • Stripping length
    8 mm
  • Transmission speed
    100 Mbps
  • Conductor cross section flexible max.
    1.5 mm²
  • Width
    53.6 mm
  • Ambient temperature (operation)
    -25 °C ... 60 °C
  • Degree of protection
    IP20
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Conductor cross section AWG min.
    24
  • Mounting position
    any (no temperature derating)
  • Supply voltage
    24 V DC
  • Nominal input current at UIN
    2.4 mA
  • Connection technology
    4-conductor
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.0
    27240400
  • ETIM 3.0
    EC001599
  • ETIM 7.0
    EC001599
  • UNSPSC 20.0
    32151602
  • Height
    129.9 mm
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Designation
    Supply for digital input modules (UI)
  • Conductor cross section solid min.
    0.2 mm²
  • Mounting type
    DIN rail
  • Note on weight specifications
    with connectors and bus base module
  • Current consumption
    max. 4 A (2 A or each group of 8 inputs)
  • Input name
    Digital inputs
  • Input filter time
    500 µs (Default)
  • Input voltage range "0" signal
    -3 V DC ... 5 V DC
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
  • ECLASS 4.1
    27240400
  • ECLASS 6.0
    27242600
  • ECLASS 9.0
    27242604
  • UNSPSC 7.0901
    43201404
  • UNSPSC 18.0
    32151602
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Conductor cross section flexible min.
    0.2 mm²
  • Net weight
    231 g
  • Power consumption
    max. 120 W (of which 800 mW with internal losses)
  • Protective circuit
    Polarity reversal protection of the inputs electronic
  • Number of inputs
    16
  • Input voltage range "1" signal
    11 V DC ... 30 V DC
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • Interference emission
    Noise emission test according to EN 61000-6-3 Class B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • UNSPSC 13.2
    32151602
  • UNSPSC 21.0
    32151602
  • ECLASS 5.0
    27242200
  • ECLASS 7.0
    27242604
  • UNSPSC 12.01
    39121311
  • UNSPSC 11
    39121311
  • UNSPSC 6.01
    43172015
  • UNSPSC 19.0
    32151602
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Description of the input
    EN 61131-2 types 1 and 3
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ETIM 6.0
    EC001599
  • Test section
    5 V supply of the local bus (UBus) / 24 V supply (I/Os) 500 V AC 50 Hz 1 min.
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • ECLASS 5.1
    27242600
  • ECLASS 10.0.1
    27242604
  • ETIM 4.0
    EC001599
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical)
  • ECLASS 11.0
    27242604

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo