Welcome to Quotebeam
Nikki Gonzales
Bryan Obida
Nick Goetz

We are online

Monday - Friday 6AM - 6PM PST

2320827 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 2320827 Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 3-phase, output: 48 V DC / 20 A
Phoenix Contact

Part#:2320827

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology (Selective Fuse Breaking), input: 3-phase, output: 48 V DC / 20 A

About the category: AC/DC power supplies are power supplies that convert alternating current from the grid into direct current that is needed to power most electronics. AC/DC power supplies are integral components in systems that make the world go round.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2320827 Phoenix Contact price in the box on the right side or send a quick quote.

2320827 Product Details

  • Height
    130 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Degree of pollution
    2
  • Discharge current to PE
    < 3.5 mA
  • Mains buffering time
    typ. 25 ms (400 V AC)
  • Protective circuit/component
    Varistor
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Output power
    960 W
  • MTBF (IEC 61709, SN 29500)
    > 890000 h (25 °C)
  • Insulation voltage output / PE
    500 V DC (routine test)
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section AWG max.
    10
  • Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
    EN 50178/VDE 0160 (PELV)
  • UL approvals
    UL Listed UL 508
  • Contact discharge
    8 kV (Test Level 4)
  • Test field strength
    10 V/m (Test Level 3)
  • Input
    2 kV (Test Level 3 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ECLASS 11.0
    27040701
  • ECLASS 4.0
    27040700
  • Depth
    179 mm
  • Degree of protection
    IP20
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Input voltage range
    3x 320 V AC ... 575 V AC
  • AC frequency range
    45 Hz ... 65 Hz
  • REACh SVHC
    Lead 7439-92-1
  • Recommended breaker for input protection
    6 A ... 16 A (AC: Characteristics B, C, D, K)
  • POWER BOOST (IBoost)
    22.5 A (-25 °C ... 40 °C permanent, UOUT = 48 V DC )
  • Connection in series
    yes
  • Active current limitation
    Approx. IBOOST = 22.5 A (for short-circuit)
  • Typical response time
    < 1 s
  • Housing material
    Steel sheet, zinc-plated
  • Assembly instructions
    alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Connection method
    Screw connection
  • Standard - Safety of transformers
    IEC 61558-2-17
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 4.1
    27040700
  • ETIM 4.0
    EC002540
  • UNSPSC 12.01
    39121004
  • Width with alternative assembly
    176 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Installation height
    4000 m
  • Nominal power consumption
    1386 VA
  • Nominal output current (IN)
    20 A (-25 °C ... 60 °C, UOUT = 48 V DC)
  • Selective Fuse Breaking (ISFB)
    100 A (12 ms)
  • Protection against overvoltage at the output (OVP)
    < 60 V DC
  • Net weight
    2.5 kg
  • Insulation voltage input / PE
    3.5 kV AC (type test)
  • Mounting position
    horizontal DIN rail NS 35, EN 60715
  • Conductor cross section flexible min.
    0.2 mm²
  • Stripping length
    10 mm
  • EMC requirements for noise emission
    EN 61000-6-3
  • Standard – Safety extra-low voltage
    IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Standard - Approval for medical use
    IEC 60601-1, 2 x MOOP
  • CSA
    CAN/CSA-C22.2 No. 60950-1-07
  • Electrostatic discharge
    EN 61000-4-2
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Fast transients (burst)
    EN 61000-4-4
  • Output
    1 kV (Test Level 2 - symmetrical)
  • Voltage
    10 V (Test Level 3)
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 5.0
    27242200
  • ETIM 3.0
    EC001039
  • ETIM 6.0
    EC002540
  • UNSPSC 6.01
    30211502
  • UNSPSC 20.0
    39121004
  • Width
    96 mm
  • Height with alternative assembly
    130 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Current consumption
    3x 2.1 A (400 V AC)
  • Type of protection
    Transient surge protection
  • Setting range of the output voltage (USet)
    30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
  • Feedback voltage resistance
    max. 60 V DC
  • Residual ripple
    < 50 mVPP (with nominal values)
  • Power loss nominal load max.
    70 W
  • Insulation voltage input/output
    4 kV AC (type test)
  • Protection class
    I
  • Conductor cross section AWG min.
    18
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    IEC 60950-1/VDE 0805 (SELV)
  • Standard - Equipment safety
    BG (design tested)
  • Standard - Safe isolation
    DIN VDE 0100-410
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Frequency range
    0.15 MHz ... 80 MHz
  • Surge voltage load (surge)
    EN 61000-4-5
  • Conducted interference
    EN 61000-4-6
  • ECLASS 6.0
    27049000
  • ETIM 7.0
    EC002540
  • UNSPSC 21.0
    39121004
  • Depth with alternative assembly
    99 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Nominal input voltage range
    3x 400 V AC ... 500 V AC
  • Frequency range DC
    0 Hz
  • Inrush current
    < 20 A (typical)
  • Nominal output voltage
    48 V DC ±1 %
  • Derating
    60 °C ... 70 °C (2.5%/K)
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Maximum power dissipation in no-load condition
    24 W
  • Efficiency
    > 93 % (at 400 V AC and nominal values)
  • Conductor cross section solid max.
    6 mm²
  • Conductor cross section flexible max.
    4 mm²
  • Screw thread
    M3
  • Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
    EN 50178
  • Rail applications
    EN 50121-4
  • Discharge in air
    15 kV (Test Level 4)
  • Comments
    Criterion A
  • I/O/S
    asymmetrical
  • ECLASS 10.0.1
    27040701
  • ECLASS 5.1
    27242200
  • ECLASS 9.0
    27040701
  • UNSPSC 11
    39121004
  • UNSPSC 18.0
    39121004
  • ECLASS 7.0
    27049002
  • UNSPSC 7.0901
    39121004
  • UNSPSC 13.2
    39121004
  • UNSPSC 19.0
    39121004

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo