Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

1135740 Phoenix Contact Electrical Circuit Protection & Load Centers

Phoenix Contact 1135740 Single-channel, electronic fuse for the protection of 24 V loads. 24VDC, 6 Amp.  Simple potential distribution using terminal blocks from the CLIPLINE complete system. With status output, reset input, and electronic interlock. For installation on DIN rail
Phoenix Contact

Part#:1135740

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Single-channel, electronic fuse for the protection of 24 V loads. 24VDC, 6 Amp. Simple potential distribution using terminal blocks from the CLIPLINE complete system. With status output, reset input, and electronic interlock. For installation on DIN rail

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Circuit Protection & Load Centers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1135740 Phoenix Contact price in the box on the right side or send a quick quote.

1135740 Product Details

  • Ambient temperature (operation)
    -30 °C ... 60 °C
  • Mounting type
    DIN rail: 35 mm
  • Number of positions
    1
  • Rated surge voltage
    0.5 kV
  • Fail-safe element
    15 A DC
  • Efficiency
    > 99 %
  • Tripping method
    E (electronic)
  • Voltage drop
    0.16 V (at 6 A)
  • Width
    6.2 mm
  • Humidity test
    96 h, 95 % RH, 40 °C
  • Degree of protection
    IP20
  • Protection class
    III
  • Type
    DIN rail module, one-piece
  • Operating voltage
    18 V DC ... 30 V DC
  • Rated current IN
    24 A DC (Total current input)
  • Waiting time after switch off of a channel
    5 s (at overload / short circuit)
  • Temperature derating
    21 A (Total current at 60°C)
  • Dielectric strength
    max. 35 V DC (Load circuit)
  • Max. capacitive load load circuit
    34000 µF (Depending on the current setting and the short-circuit current available)
  • Conductor cross section, flexible, with ferrule, with plastic sleeve
    0.2 mm² ... 2.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve
    0.2 mm² ... 2.5 mm²
  • Input voltage reset input
    7 V DC ... 30 V DC (Reset with falling edge)
  • Connection name
    Main circuit OUT
  • Standards/specifications
    EN 61000-6-2 EMC – Immunity for industrial areas
  • Vibration
    B
  • ECLASS 10.0.1
    27140401
  • Height
    105.8 mm
  • Altitude
    ≤ 3000 m up to 52 °C (amsl (above mean sea level))
  • Shock (operation)
    30g (IEC 60068-2-27, Test Ea)
  • Flammability rating according to UL 94
    V-0
  • Fuse type
    electronic
  • Rated voltage
    24 V DC
  • Feedback resistance
    max. 35 V DC
  • Power dissipation
    typ. 0.15 W (No-load operation)
  • Required backup fuse
    Only required if Imax of the power supply > the short-circuit switching capacity. Integrated failsafe element.
  • Short-circuit switching capacity
    300 A
  • Overvoltage switch-off shutdown load circuit
    ≥ 30.5 V DC (active)
  • Stripping length
    8 mm
  • Conductor cross section AWG
    24 ... 12
  • Channel LED off
    off (Channel switched off)
  • Channel LED red
    lit (Channel switched off, over- or undervoltage active)
  • Connection method
    Push-in connection
  • EMC
    B
  • ECLASS 11.0
    27140401
  • ECLASS 9.0
    27141116
  • Depth
    55.6 mm (incl. DIN rail 7.5 mm)
  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Vibration (operation)
    10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
  • Color
    traffic grey A RAL 7042
  • Degree of pollution
    2
  • Measuring tolerance I
    ± 15 %
  • Closed circuit current I0
    typ. 8 mA
  • Module initialization time
    1 s
  • MTBF (IEC 61709, SN 29500)
    26315789 h (at 25 °C with 21 % load)
  • Undervoltage switch-off load circuit
    ≤ 17.8 V DC (active)
  • Output current status output
    max. 0.015 A (Short-circuit-proof)
  • Pulse length reset input
    ≥ 50 ms (High)
  • Current consumption reset input
    typ. 0.4 mA (at 24 V DC)
  • Channel LED green
    lit (Channel switched on)
  • Designation
    Shipbuilding approval
  • Temperature
    D
  • REACh SVHC
    Lead 7439-92-1
  • Shutdown time load circuit
    ≤ 10 ms (for short circuit > 2.0 x IN)
  • Output voltage status output
    24 V DC (Error)
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • Voltage reset input
    < 5 V DC (Low state)
  • Channel LED yellow
    lit (Channel switched on, channel load > 80% )
  • Humidity
    B
  • Identification
    DNV GL
  • Enclosure
    A

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1135740

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo