About the product: Axioline Smart Elements, Digital input module, PROFIsafe, Safe digital inputs: 8 (1-channel assignment), 4 (2-channel assignment), 24 V DC, connection method: 3-conductor, degree of protection: IP20
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 1079241 Phoenix Contact price in the box on the right side or send a quick quote.
1079241 Product Details
- Number 1
- Caption Dimensions
- Depth 62 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Number of inputs 8 (1-channel assignment)
- ECLASS 11.0 27242604
- Designation EN 62061
- Conductor cross section AWG max. 16
- Input filter time 1.5 ms
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Nominal voltage UN 24 V DC (from UP)
- Number of outputs 2
- Net weight 36 g
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (operation) -25 °C ... 60 °C
- Operating mode PROFIsafe 2.4, PROFIsafe 2.6.1
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Category 3 (1-channel assignment)
- Note on the connection method Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
- Conductor cross section solid min. 0.25 mm²
- Conductor cross section AWG min. 24
- Transmission speed See system in which you use the Smart Element.
- Cable length max. 200 m (200 m from the clock output to the safe input (total based on forward and return path))
- Input current range “1“ signal min. 2 mA
- Short-circuit protection Yes
- Color zinc yellow RAL 1018
- Maximum altitude ≤ 3000 m (Above sea level)
- Protection external fusing via the system in which the Smart Element is used
- Width 14.9 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Air pressure (storage/transport) 66 kPa ... 108 kPa
- Height 62.2 mm
- Degree of protection IP20
- Conductor cross section flexible min. 0.25 mm²
- Input name Safe digital inputs
- Connection technology 3-conductor
- Protective circuit Surge protection of the supply voltage electronic (35 V, 0.5 s)
- Switching frequency max. 10 Hz
- Degree of pollution 2 (EN 60664-1)
- Additional text using card edge connectors
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Interference emission Noise emission test as per EN 61000-6-4 Class A (industrial applications)
- ECLASS 10.0.1 27242604
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of protection at installation location min. IP54
- Air pressure (operation) 70 kPa ... 108 kPa
- Conductor cross section solid max. 1.5 mm²
- Stripping length 8 mm
- Description of the input EN 61131-2, type 3
- Input voltage range "0" signal -3 V DC ... 5 V DC
- Nominal input voltage UIN 24 V DC
- Input current range "0" signal max. 1.5 mA
- Mounting type Smart Element slot
- Supply voltage 24 V DC (using card edge connectors)
- Power consumption min. 154 mW
- Performance level (PL) d (1-channel assignment)
- Nominal input current at UIN typ. 2.7 mA
- Limiting continuous current max. 0.5 A DC (per clock output)
- Mounting position any
- Current consumption min. 8 mA (Power supply from Up with 19.2 V DC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
- Safety Integrity Level Claim Limit (SIL CL) 2 (1-channel assignment)
- Air clearances and creepage distances IEC 60664-1
- REACh SVHC Lead 7439-92-1
- Safety Integrity Level (SIL) 2 (1-channel assignment)
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2 kV
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Overvoltage category II (IEC 60664-1)
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Test intensity 2, Criterion APower supply: 0.5 kV/0.5 kV (symmetrical/unsymmetrical)Signal lines: 1.0 kV/2.0 kV (symmetrical/unsymmetrical)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 9.0 27242604
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨