1065976 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 1065976 TRIO POWER primary-switched power supply in IP67 die-cast housing, input: 1-phase, output: 24 V DC / 8 A
Phoenix Contact

Part#:1065976

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: TRIO POWER primary-switched power supply in IP67 die-cast housing, input: 1-phase, output: 24 V DC / 8 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1065976 Phoenix Contact price in the box on the right side or send a quick quote.

1065976 Product Details

  • Depth
    53 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (Derating >60°C: 2.5 %/K)
  • Degree of pollution
    3
  • Height
    240 mm
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Permissible humidity (operation)
    ≤ 100 % (at 25 °C, non-condensing)
  • Nominal input voltage range
    100 V AC ... 240 V AC
  • Current consumption
    2.2 A (100 V AC)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP67
  • Ambient temperature (start-up type tested)
    -25 °C
  • Input voltage range
    100 V AC ... 240 V AC 10 %
  • Discharge current to PE
    < 3.5 mA
  • Nominal power consumption
    285 VA
  • Protective circuit/component
    Varistor
  • Derating
    > 60 °C ... 70 °C (2.5%/K)
  • Connection in parallel
    no
  • Output power
    192 W
  • Power loss nominal load max.
    < 18 W (120 V AC)
  • Protection class
    I
  • Standards/regulations
    EN/IEC 60529
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Electrostatic discharge
    EN 61000-4-2
  • Electromagnetic HF field
    EN 61000-4-3
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Voltage dip
    0 %
  • Frequency
    50 Hz
  • REACh SVHC
    Lead 7439-92-1
  • Width
    136 mm
  • Max. permissible relative humidity (operation)
    ≤ 100 % (at 25 °C, non-condensing)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • AC frequency range
    50 Hz ... 60 Hz ±10 %
  • Inrush current
    ≤ 25 A (typical)
  • Frequency range (fN)
    50 Hz ... 60 Hz ±10 %
  • Input fuse
    6.3 A (internal (device protection))
  • Type of protection
    Transient surge protection
  • Nominal output voltage
    24 V DC ±1 %
  • Feedback voltage resistance
    ≤ 35 V DC
  • Control deviation
    < 1 % (change in load, static 10 % ... 90 %)
  • Efficiency
    typ. 91 % (120 V AC)
  • Insulation voltage input/output
    3 kV AC (type test)
  • Standard designation
    Degrees of protection provided by enclosures (IP code)
  • Conducted noise emission
    EN 55016
  • Noise emission
    EN 55016
  • Test field strength
    10 V/m (Test Level 3)
  • Voltage
    230 V AC
  • Surge voltage load (surge)
    EN 61000-4-5
  • Number of periods
    1 period
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Installation height
    ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m)
  • Dielectric strength maximum
    ≤ 300 V AC 15 s
  • Mains buffering time
    > 15 ms (120 V AC)
  • Power factor (cos phi)
    0.93
  • Nominal output current (IN)
    8 A
  • Connection in series
    No
  • Maximum power dissipation in no-load condition
    < 8 W (120 V AC)
  • MTBF (IEC 61709, SN 29500)
    > 1800000 h (25 °C)
  • Assembly instructions
    Alignable: 20 mm horizontally, 50 mm vertically above, 100 mm vertically below
  • Type of locking
    screw locking
  • Harmonic currents
    EN 61000-3-2
  • Contact discharge
    6 kV (Test Level 3)
  • Comments
    Criterion A
  • Signal
    1 kV (Test Level 2 - asymmetrical)
  • Voltage dips
    EN 61000-4-11
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 9.0
    27040701
  • Recommended breaker for input protection
    6 A ... 16 A (US/CAN: branch circuit protection < 20 A) (Characteristic B, C, D, K or comparable)
  • Dynamic Boost (IDyn.Boost)
    12 A (5 s)
  • Protection against overvoltage at the output (OVP)
    ≤ 30 V DC
  • Residual ripple
    ≤ 10 mVPP
  • Net weight
    1.5 kg
  • Connection method
    7/8″ circular connector
  • Range of positions
    4 Socket
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Frequency range
    0.15 MHz ... 80 MHz
  • Input
    2 kV (Test Level 4 - symmetrical)
  • Fast transients (burst)
    EN 61000-4-4
  • Conducted interference
    EN 61000-4-6
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

1065976

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo