About the product: Axioline P, Analog input module, Analog inputs: 8, 4 mA ... 20 mA, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, degree of protection: IP20
About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.
Check out the 1052429 Phoenix Contact price in the box on the right side or send a quick quote.
1052429 Product Details
- Height 126.1 mm
- Ambient temperature (operation) -40 °C ... 70 °C (Standard)
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 16
- Maximum altitude 2000 m
- Current consumption max. 135 mA
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- ATEX DEMKO 20 ATEX 2334XII 3G Ex ec IIC T4 Gc
- China RoHS Environmentally Friendly Use Period = 25;
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Designation Supply of the Axioline P local bus UBus
- Conductor cross section flexible max. 1.5 mm²
- Mounting type DIN rail
- Net weight 352.9 g
- Supply voltage range 19.2 V DC ... 30 V DC (via bus base module (UL) at AXL P BK...)
- IECEx IECEx UL 20.0002XEx ec IIC T4 Gc
- Overvoltage category II
- ECLASS 9.0 27242601
- Width 53.6 mm
- Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline P: system and installation” user manual.
- Conductor cross section solid min. 0.2 mm²
- Degree of pollution 2
- Test section 5 V supply of the local bus (UBus) / functional ground 500 V AC 62 Hz 1 min.
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
- Interference emission Noise emission test as per EN 61000-6-4 Class A
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- Note on dimensions The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (operation) 70 kPa ... 106 kPa (up to 2000 m above sea level)
- Connection method Bus base module
- Stripping length 8 mm
- Note on weight specifications with connectors and bus base module
- Transmission speed 100 Mbps
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- UL, USA/Canada Class I, Div. 2, Groups A, B, C, D T4Class I, Zone 2, IIC T4
- ECLASS 10.0.1 27242601
- Depth 77.14 mm
- Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 2000 m above sea level)
- Conductor cross section flexible min. 0.2 mm²
- Color traffic grey A RAL 7042
- Supply voltage 5 V DC (via bus base module)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27242601
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
Shipping and Delivery Worldwide
calculate cost and time at Checkout
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨