1050201 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 1050201 Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.
Phoenix Contact

Part#:1050201

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Temperature transducer, converts signals from resistance temperature detectors and resistors into analog 0/4 - 20 mA signals. Freely programmable, Push-in connection, SIL, 3-way electrical isolation, standard configuration.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1050201 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Depth
    114.5 mm
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Input signal range
    0 Ω ... 50 kΩ
  • Sensor input current
    10 µA ... 210 µA (Up to 2x 210 µA with 3-conductor technology)
  • Current output signal
    0 mA ... 20 mA
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • No. of channels
    1
  • Alignment zero
    ± 5 %
  • Interference emission
    EN 61000-6-4
  • Color
    gray
  • Height
    116 mm
  • Altitude
    ≤ 5000 m
  • Temperature measuring range
    -200 °C ... 850 °C (Range depending on the sensor type)
  • Potentiometer resistance range
    0 Ω ... 50 kΩ
  • Measuring range span
    ≥ 50 K
  • Nominal supply voltage
    24 V DC
  • Stripping length
    8 mm
  • Transmission error, typical
    0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
  • Housing material
    PA 6.6-FR
  • Degree of pollution
    2
  • IECEx
    Ex ec ic IIC T4 Gc
  • DNV GL-Temperature
    B
  • Identification
    2
  • EMC
    B
  • ECLASS 4.1
    27210120
  • ETIM 3.0
    EC001446
  • UNSPSC 11
    39121008
  • UNSPSC 18.0
    41112105
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Rated insulation voltage
    300 Vrms
  • Signal output
    Current output
  • Max. current output signal
    ≥ 21 mA
  • Behavior in the event of a sensor error
    As per NE 43 or can be freely defined
  • Conductor cross section AWG
    24 ... 16
  • Status display
    Green LED (supply voltage, PWR)
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Designation
    Safety Integrity Level (SIL, IEC 61508)
  • Standards/regulations
    GB 3836.1
  • Typical deviation from the measuring range final value
    1 %
  • DNV GL-Humidity
    B
  • Certificate
    DNV GL TAA00000AG
  • Temperature
    B
  • ECLASS 10.0.1
    27210129
  • ECLASS 4.0
    27210120
  • ECLASS 6.0
    27210120
  • ETIM 7.0
    EC002919
  • UNSPSC 12.01
    39121008
  • UNSPSC 20.0
    41112105
  • Noise emission
    EN 61000-6-4
  • Ambient temperature (operation)
    49 °C
  • Degree of protection
    IP20
  • Sensor types (RTD) that can be used
    Pt, Ni, Cu sensors: 2, 3, 4-wire
  • Configurable/programmable
    Yes
  • Output ripple (current)
    < 15 µAPP
  • Connection method
    Push-in connection
  • Power consumption
    ≤ 1 W
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Alignment span
    ± 5 %
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)
  • Conformance
    CE-compliant, additionally EN 61326
  • DNV GL-EMC
    B
  • Humidity
    B
  • Vibration
    A
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27210120
  • ETIM 2.0
    EC001446
  • ETIM 6.0
    EC002919
  • UNSPSC 19.0
    41112105
  • Width
    12.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Max. permissible overall conductor resistance
    50 Ω (Per cable)
  • Load/output load current output
    ≤ 600 Ω
  • Power dissipation
    ≤ 0.76 W
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Temperature coefficient, typical
    0.01 %/K
  • Step response (0–99%)
    typ. 1 s
  • Overvoltage category
    II
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • DNV GL-Vibration
    A
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 11.0
    27210129
  • ECLASS 7.0
    27210120
  • ECLASS 9.0
    27210129
  • UNSPSC 6.01
    30211506
  • UNSPSC 13.2
    41112105
  • ATEX
     II 3 G Ex ec ic IIC T4 Gc
  • Additional text
    and EN 61326
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27210120
  • ETIM 4.0
    EC001446
  • UNSPSC 7.0901
    39121008
  • UNSPSC 21.0
    41112105

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo