8036873 Festo Flow Sensors

Festo 8036873 flow sensor SFAW-32-TG34-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to RoHS
Festo

Part#:8036873

Manufacturer:Festo

Alt. Part#:SFAW-32-TG34-E-PNLK-PNVBA-M12

Product Lifecycle:Active

Get a quick Quote!

About the product: flow sensor SFAW-32-TG34-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to RoHS

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8036873 Festo price in the box on the right side or send a quick quote.

8036873 Product Details

  • Type code
    SFAW
  • Note on materials
    RoHS-compliant
  • Flow measuring range start value
    1.8 l/min
  • Information on operating pressure
    Max. 12 bar at 40°C Max. 6 bar at 100 °C
  • Repetition accuracy of flow rate value
    < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS
  • Switching element function
    N/C contact/N/O contact switchable
  • Min. load resistance of voltage output
    15 kOhm
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, process data width OUT
    0 Byte
  • IO-Link®, service data contents IN
    32 bit volume measurement
  • Electrical connection
    5-pin Plug, straight
  • Fluid connector
    Internal thread G3/4
  • Flow direction
    Unidirectional P1 -> P2
  • Operating medium
    Liquid media Neutral liquids
  • Accuracy of flow rate
    ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS
  • Temperature co-efficient margin in ± %FS/K
    Typ. ±0.05% FS/K
  • Max. output current
    100 mA
  • Short-circuit protection
    yes
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, process data width IN
    3 Byte
  • IO-Link®, data memory required
    500 byte
  • Housing material
    PA-reinforced
  • Materials in contact with the media
    EPDM (peroxide) PA6T/6I-reinforced
  • KC characters
    KC EMC
  • Method of measurement
    Flow rate: vortex Temperature: PT1000
  • Operating pressure
    0 bar ... 12 bar
  • Nominal temperature
    23 °C
  • Switching function
    Window comparator Freely programmable
  • Flow characteristic curve, start value
    0 l/min
  • Protocol
    IO-Link®
  • IO-Link®, port class
    A
  • IO-Link®, process data content IN
    1 bit BDC (volume monitoring) 2 bit BDC (flow monitoring)
  • Mounting position
    Any
  • Degree of protection
    IP65
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Measured variable
    Flow rate Temperature
  • Temperature of medium
    0 °C ... 90 °C
  • Information on operating and pilot media
    Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured.
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Max. load resistance of current output
    500 Ohm
  • Flow characteristic curve, end value
    32 l/min
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, minimum cycle time
    5 ms
  • Reverse polarity protection
    for all electrical connections
  • Product weight
    530 g
  • Corrosion resistance class (CRC)
    3 - High corrosion stress
  • Symbol
    00995566
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Flow measuring range end value
    32 l/min
  • Ambient temperature
    0 °C ... 50 °C
  • Accuracy of temperature in ± °C
    2 °C
  • Analog output
    0 - 10 V 1 - 5 V
  • Overload protection
    Available
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, SIO mode support
    Yes
  • DC operating voltage range
    18 V ... 30 V
  • Max. cable length
    20 m for IO-Link® operation 30 m
  • Displayable unit(s)
    US gal °F

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 8036873 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

8036873

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo