Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

8036872 Festo Flow Sensors

Festo 8036872 flow sensor SFAW-32T-TG12-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to RoH
Festo

Part#:8036872

Manufacturer:Festo

Alt. Part#:SFAW-32T-TG12-E-PNLK-PNVBA-M12

Product Lifecycle:Active

Get a quick Quote!

About the product: flow sensor SFAW-32T-TG12-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to RoH

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8036872 Festo price in the box on the right side or send a quick quote.

8036872 Product Details

  • Measured variable
    Flow rate Temperature
  • Information on operating pressure
    Max. 12 bar at 40°C Max. 6 bar at 100 °C
  • Accuracy of temperature in ± °C
    2 °C
  • Switching element function
    N/C contact/N/O contact switchable
  • Flow characteristic curve, end value
    32 l/min
  • Protocol
    IO-Link®
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, service data contents IN
    32 bit volume measurement
  • Max. cable length
    20 m for IO-Link® operation 30 m
  • Degree of protection
    IP65
  • Type code
    SFAW
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Method of measurement
    Flow rate: vortex Temperature: PT1000
  • Temperature measuring range end value
    90 °C
  • Operating medium
    Liquid media Neutral liquids
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Max. output current
    100 mA
  • Max. load resistance of current output
    500 Ohm
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, process data width OUT
    0 Byte
  • DC operating voltage range
    18 V ... 30 V
  • Materials in contact with the media
    EPDM (peroxide) PA6T/6I-reinforced
  • Symbol
    00995566
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Flow measuring range start value
    1.8 l/min
  • Operating pressure
    0 bar ... 12 bar
  • Accuracy of flow rate
    ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS
  • Temperature co-efficient margin in ± %FS/K
    Typ. ±0.05% FS/K
  • Analog output
    0 - 10 V 1 - 5 V
  • Min. load resistance of voltage output
    15 kOhm
  • Overload protection
    Available
  • IO-Link®, port class
    A
  • IO-Link®, process data width IN
    5 Byte
  • IO-Link®, minimum cycle time
    5 ms
  • Mounting position
    Any
  • Displayable unit(s)
    US gal °F
  • Flow measuring range end value
    32 l/min
  • Information on operating and pilot media
    Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured.
  • Nominal temperature
    23 °C
  • Switching function
    Window comparator Freely programmable
  • Flow characteristic curve, start value
    0 l/min
  • Short-circuit protection
    yes
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, data memory required
    500 byte
  • Electrical connection
    5-pin Plug, straight
  • Housing material
    PA-reinforced
  • Fluid connector
    Internal thread G1/2
  • KC characters
    KC EMC
  • Note on materials
    RoHS-compliant
  • Flow direction
    Unidirectional P1 -> P2
  • Temperature measuring range start value
    0 °C
  • Temperature of medium
    0 °C ... 90 °C
  • Ambient temperature
    0 °C ... 50 °C
  • Repetition accuracy of flow rate value
    < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS
  • Temperature characteristic curve end value
    100 °C
  • Temperature characteristic curve start value
    0 °C
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, process data content IN
    1 bit BDC (temperature monitoring) 2 bit BDC (flow monitoring)
  • Reverse polarity protection
    for all electrical connections
  • Product weight
    400 g
  • Corrosion resistance class (CRC)
    3 - High corrosion stress

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 8036872 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

8036872

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo